Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Am J Emerg Med ; 30(7): 1025-31, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21908143

RESUMO

OBJECTIVES: We sought to assess the anatomical distribution of traumatic pneumothoraces (PTXs) on chest computed tomography (CT) to develop an optimized protocol for PTX screening with ultrasound in the emergency department (ED). METHODS: We performed a retrospective review of all chest CTs performed in one ED between January 2005 and December 2008 according to presence, location, and size of PTX. Pneumothoraces were then measured and categorized into 14 anatomical regions for each hemithorax. RESULTS: A total of 277 (3.8%) PTXs were identified, with 26 bilateral PTX, on 3636 chest CTs performed during the study period. Etiology was blunt (85%) or penetrating trauma (15%). Eighty-three (45%) PTXs were radiographically occult on initial chest x-ray. One hundred eighty-three (66%) PTX had no chest tube at the time of CT. For both hemithoraces, the distribution demonstrated increasing PTX frequency and size from lateral to medial and from superior to inferior. Region 12 (parasternal, intercostal spaces [ICS] 7-8) was involved in 68% of PTX on either side; region 9 (parasternal, ICS 5-6), in 67% on the left and in 52% on the right; and region 11 (lateral to midclavicular line, ICS 7-8), in 46% on the left and in 53% on the right. The largest anterior-to-posterior PTX dimension was seen in region 12. CONCLUSIONS: Our results indicate that 80.4% of right- and 83.7% of left-sided traumatic PTXs would be identified by scanning regions 9, 11, and 12. These findings suggest that a standardized protocol for PTX screening with ultrasound should include these regions.


Assuntos
Pneumotórax/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tubos Torácicos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumotórax/classificação , Pneumotórax/diagnóstico por imagem , Radiografia Torácica , Estudos Retrospectivos , Sensibilidade e Especificidade , Tórax/patologia , Tomografia Computadorizada por Raios X , Ultrassonografia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/patologia , Ferimentos Penetrantes/diagnóstico por imagem , Ferimentos Penetrantes/patologia , Adulto Jovem
2.
Ther Umsch ; 68(8): 468-72, 2011 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-21796600

RESUMO

Adhesions occur with a high incidence after intra-abdominal surgery but can also develop due to infections, radiation or for idiopathic reasons. The formation of adhesions is initiated by tissue damage and is the result of peritoneal tissue repair involving the activation of the inflammatory system and the coagulation cascade. Acute small bowel obstruction is one of the most common complications and should be diagnosed rapidly using clinical examination and radiological imaging. A complete obstruction is life threatening and in a high percentage of patients requires rapid surgical intervention by laparotomy or laparoscopy depending on the clinical situation and the patients history. Despite numerous investigations, there is no reliable, commonly used method to prevent intra-abdominal adhesions. Minimizing tissue damage and foreign body exposure, avoiding spillage of intestinal and biliary contents as well as a laparoscopic approach seem to have a beneficial effect on the formation of intra-abdominal adhesions.


Assuntos
Abdome Agudo/etiologia , Dor Abdominal/etiologia , Aderências Teciduais/diagnóstico , Algoritmos , Meios de Contraste , Diatrizoato de Meglumina , Humanos , Obstrução Intestinal/diagnóstico , Obstrução Intestinal/cirurgia , Aderências Teciduais/prevenção & controle , Aderências Teciduais/cirurgia , Tomografia Computadorizada por Raios X , Ultrassonografia , Vísceras/cirurgia
3.
Ultrasound Med Biol ; 36(8): 1267-72, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20691916

RESUMO

Point-of-care ultrasound is being increasingly implemented in resource-poor settings in an ad hoc fashion. We developed a focused maternal ultrasound-training program for midwives in a rural health district in Zambia. Four hundred forty-one scans were recorded by 21 midwives during the 6-month study period. In 74 scans (17%), the ultrasound findings prompted a change in clinical decision-making. Eight of the midwives were evaluated with a 14-question observed structured clinical examination (OSCE) and demonstrated a slight overall improvement with mean scores at 2 and 6 months of 10.0/14 (71%) and 11.6/14 (83%), respectively. Our pilot project demonstrates that midwives in rural Zambia can be trained to perform basic obstetric ultrasound and that it impacts clinical decision-making. Ultrasound skills were retained over the study period. More data is necessary to determine whether the introduction of ultrasound ultimately improves outcomes of pregnant women in rural Zambia.


Assuntos
Tocologia/estatística & dados numéricos , População Rural/estatística & dados numéricos , Ultrassonografia Pré-Natal/estatística & dados numéricos , Feminino , Humanos , Mães , Projetos Piloto , Gravidez , Zâmbia/epidemiologia
4.
Ann Emerg Med ; 56(6): 660-7, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20538370

RESUMO

STUDY OBJECTIVE: Training physicians in new skills through classroom-based teaching has inherent cost and time constraints. We seek to evaluate whether Web-based didactics result in similar knowledge improvement and retention of basic ultrasonographic principles and the Extended Focused Assessment with Sonography for Trauma (EFAST) compared with the traditional method. METHODS: Physicians from 2 German emergency departments were randomized into a classroom group with traditional lectures and a Web group who watched narrated lectures online. All participants completed a pre- and posttest and a second posttest 8 weeks later. Both groups underwent hands-on training after the first posttest. A control group completed the 2 initial tests without didactic intervention. RESULTS: Fifty-five subjects participated in the study. Both the classroom and Web group showed significant improvement in pre- and posttest 1 scores (75.9% versus 93.9% and 77.8% versus 92.5%; P<.001 for both), with similar knowledge retention after 8 weeks (88.6% and 88.9%; P=.87). No statistically significant difference in mean test scores could be found between the 2 groups at each point: -1.9% (95% confidence interval [CI] -5.2% to 1.4%) for the pretest, 1.4% (95% CI -0.6% to 3.4%) for posttest 1, and -0.3% (95% CI -3.9% to 3.3%) for posttest 2. The control group showed no learning effect without intervention (83.3% versus 82.8%, ; P=.88). CONCLUSION: Web-based learning provides the potential to teach physicians with greater flexibility than classroom instruction. Our data suggest that Web-based ultrasonography and EFAST didactics are comparable to traditional classroom lectures and result in similar knowledge retention.


Assuntos
Instrução por Computador , Medicina de Emergência/educação , Ultrassonografia , Ferimentos e Lesões/diagnóstico por imagem , Comportamento do Consumidor , Avaliação Educacional , Medicina de Emergência/instrumentação , Serviço Hospitalar de Emergência , Feminino , Alemanha , Humanos , Masculino
5.
AJR Am J Roentgenol ; 179(4): 911-6, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12239036

RESUMO

OBJECTIVE: Although multidetector CT (MDCT) with retrospectively ECG-gated image reconstruction has been shown to permit noninvasive visualization of the coronary arteries, the 125-250 msec required for image acquisition frequently causes motion artifacts. We investigated the influence of a patient's heart rate on the presence of motion artifacts and on accuracy of stenosis detection on contrast-enhanced MDCT. MATERIALS AND METHODS: In 100 patients, MDCT was performed, and ECG-gated cross-sectional images were retrospectively reconstructed. From the 10 data sets obtained for each patient (reconstructed at 0-90% of the cardiac cycle in increments of 10%), we chose the best data set for every coronary artery. The images of the arteries were evaluated for occurrence of artifacts and the presence of high-grade stenosis (diameter reduction exceeding 70%) or occlusions. MDCT results were compared with coronary angiographic findings. RESULTS: Of the 400 coronary arteries, 115 (29%) could not be evaluated because of motion artifacts (n = 84) or other reasons (n = 31). Overall, 51 (49%) of 104 stenoses were revealed on MDCT. For detecting stenosis in those arteries that we could evaluate, MDCT had a sensitivity of 91% (51 of 56 stenoses detected) and a specificity of 89%. As the heart rate increased, the number of arteries that could be evaluated decreased, and overall sensitivity for stenosis detection decreased from 62% (heart rate < or = 70 beats per minute) to 33% (heart rate > 70 beats per minute). CONCLUSION: MDCT can reveal coronary stenoses, but the usefulness of MDCT as an aid in accurately evaluating stenoses decreases as a patient's heart rate increases.


Assuntos
Meios de Contraste , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Frequência Cardíaca , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Eletrocardiografia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...